ETA Termination and Testing Technician (TTT): free practice test

TTT is ETA's vendor-neutral certification for terminating, connecting, testing and troubleshooting the fiber, UTP and coax that link IP security and voice, data and video devices. The written exam has 75 questions in 2 hours with a 75% pass mark, across 13 competency categories from camera bandwidth and fiber transceivers to PoE and Ethernet over coax. A hands-on course comes first; this prep covers only the written exam.

Premium: 3,000 practice questions, 6 full mock exams, 800 flashcards and 60 comprehensive key notes, topic by topic. See the study path ·

Or open the free ETA TTT study dashboard: flashcards, notes and your Readiness Score, no signup →

About the ETA TTT exam

TTT is ETA's vendor-neutral certification for terminating, connecting, testing and troubleshooting the fiber, UTP and coax that link IP security and voice, data and video devices. The written exam has 75 questions in 2 hours with a 75% pass mark, across 13 competency categories from camera bandwidth and fiber transceivers to PoE and Ethernet over coax. A hands-on course comes first; this prep covers only the written exam.

What's on the exam

ETA TTT
Network Cabling for Physical Security Systems
7 key facts
Fiber Cabling, Distance and NEC Ratings
6 key facts
Fiber Safety, Connectors and Mechanical Splices
7 key facts
CCTV Fiber Transceivers and Optical Budgets
6 key facts
UTP Cabling and Structured Cabling Layout
7 key facts
UTP Connectors, Testers and Network Troubleshooting
8 key facts
Power over Ethernet for Security Devices
7 key facts
Coax for Ethernet and PoE
6 key facts

Each branch is a topic in the official outline. Members see every key fact on the full mind map. Read the free study guide →

How to pass the ETA TTT exam

  • TTT is written for physical security work: expect camera bandwidth sums, NVR uplinks, PoE budgets and long camera runs rather than data center topics.
  • Learn the IEEE PoE types in volts and watts (802.3af, 802.3at, 802.3bt Types 3 and 4) and practise switch power budget arithmetic.
  • Know what each tester proves: a continuity tester checks the wire map, a qualification tester checks link quality and speed, and ping and online tools check packet loss, latency and bandwidth.
  • 75 questions in 2 hours is 96 seconds each, and you need 75%. Bring a non-programmable calculator for bandwidth, dB budgets and PoE sums.

Save your results and get your Readiness Score

Create a free account after the test: your score by topic, a mistakes bank, the complete study notes for the first topic, flashcards and the RCDD Numbers & Formulas Sheet.

Take the test first

What's in the premium ETA TTT prep

Premium ETA TTT prep is studied one topic at a time. Each step starts with that topic's key notes and flashcard deck, then its own question sets of 25, so you master one topic before you move to the next. When every topic is strong, the 6 full mock exams show you're ready.

3,000practice questions, every answer explained
6full-length mock exams, 75 questions each, timed
800flashcards with spaced repetition, sorted by topic
60comprehensive key notes across 8 topics

Your step-by-step study path

  1. 1
    Network Cabling for Physical Security Systems8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Notes free with an account
  2. 2
    Fiber Cabling, Distance and NEC Ratings8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  3. 3
    Fiber Safety, Connectors and Mechanical Splices8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  4. 4
    CCTV Fiber Transceivers and Optical Budgets8 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  5. 5
    UTP Cabling and Structured Cabling Layout7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  6. 6
    UTP Connectors, Testers and Network Troubleshooting7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  7. 7
    Power over Ethernet for Security Devices7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  8. 8
    Coax for Ethernet and PoE7 key notes, 100 flashcards, then 375 practice questions in 15 sets of 25
    Premium
  9. Final step: 6 full mock exams75 questions each, timed like test day. Pass them, then book your exam.
    Premium
Free with an account

Read the complete ETA TTT study notes for “Network Cabling for Physical Security Systems”

Our first full set of comprehensive notes, about 12 minutes of reading: Bandwidth of security devices · Sizing switch uplinks and the NVR link · Using the internet for security systems · From coax to UTP, a worked exam example, the traps examiners use and a one-minute recap. Create a free account to read it and see how premium notes work before you decide.

Open the free dashboard

Study tools included

3,000 practice questions

3,000 exam-style questions per exam, organized topic by topic in sets of 25. Every answer explained, with the rule it comes from.

6 full mock exams

6 full-length timed mock exams per exam, with real question counts and time limits, so test day feels like practice day.

Exam Readiness Score

One 0 to 100 number that tells you when you're ready to book. Reach 80 and you're covered by our Pass Guarantee.

800 flashcards + spaced repetition

800 flashcards per exam, in a deck for each topic, that come back right before you'd forget them. Five minutes a day keeps every number fresh.

60 comprehensive key notes

60 key notes per exam, split across its topics and each explained in full: the concepts, worked exam examples, the traps examiners use and a quick recap. Your first set is free with an account.

Mind maps

See the whole exam on one screen: every topic and the facts under it.

Sample questions with answers

These are the questions in the free test above, with answers. Try the test first. You'll learn more by getting some wrong.

1. A PoE switch feeds 24 IP cameras, each streaming about 6 Mb/s, and has a 100 Mb/s uplink to the NVR. What is the problem?
Answer: The 144 Mb/s total exceeds the uplink; use a 1 Gb/s uplink. The uplink carries every camera's stream at once: 24 x 6 = 144 Mb/s, more than a 100 Mb/s link can carry, so video drops frames. Size uplinks for the total load plus headroom, here a gigabit copper or fiber uplink. Switches forward streams; they don't compress them.
2. An owner wants to watch 4 cameras remotely at 2 Mb/s each. The site's internet service is 100 Mb/s down and 5 Mb/s up. What limits remote viewing?
Answer: The 5 Mb/s upload, below the 8 Mb/s the four streams need. Remote viewing sends video out of the site, so the upload speed matters: 4 x 2 = 8 Mb/s needs more than the 5 Mb/s available. Options are a faster upload, lower-bitrate substreams for remote viewing, or fewer cameras at once. The download speed matters only for traffic coming in.
3. A gigabit IP camera link must run 1.2 km over an existing 62.5/125 µm (OM1) multimode fiber. Will standard 1000BASE-SX transceivers work?
Answer: No; SX on OM1 reaches only about 275 m, so use single-mode. 1000BASE-SX reaches only about 220 to 275 m on 62.5 µm fiber because modal dispersion limits bandwidth. The 2 km figure is 100BASE-FX at a lower data rate. For 1.2 km use single-mode fiber with 1000BASE-LX or similar transceivers rated for that distance.
4. A nonconductive fiber cable will run vertically in a shaft between floors, not in an air-handling space. What is the minimum NEC listing it needs?
Answer: OFNR (riser). Vertical runs in shafts between floors need riser-rated cable: OFNR for nonconductive fiber. Plenum OFNP may substitute, but riser is the minimum. OFNG is for general use on one floor, OFCR is for cable with metallic members, and unlisted cable is limited to 50 ft inside the building.
5. A technician says an 850 nm multimode CCTV transceiver is safe to look into because only a faint red glow is visible. What is the correct response?
Answer: Disagree; most of the 850 nm power is invisible, so use a meter. The eye barely sees 850 nm, so the faint glow hides how much power is actually entering the eye and the blink reflex may not protect it. Never look into a fiber or transceiver port; check for light with a power meter or a video probe. VCSELs at 850 nm are lasers too.
6. A pre-polished cleave-and-crimp connector tests high loss, and a visual fault locator shows a bright glow at the connector body. What is the most likely cause?
Answer: The fiber is not butted cleanly against the internal stub fiber. Cleave-and-crimp connectors work like a mechanical splice: the field fiber must be cleaved well and pushed fully against a factory stub fiber in index-matching gel. A poor cleave or short insertion leaves a gap that leaks light, which the VFL shows. Re-strip, recleave and re-terminate.
7. A pair of 850 nm multimode CCTV transceivers has a 10 dB optical budget. The link has 1.2 km of fiber at 3.5 dB/km, 4 connector pairs at 0.75 dB and 1 mechanical splice at 0.3 dB. Will it work, and with what margin?
Answer: Yes, with about 2.5 dB of margin. Loss is 1.2 x 3.5 = 4.2 dB of fiber, 3.0 dB of connectors and 0.3 dB for the splice, 7.5 dB in total. The budget is 10 dB, so the margin is 2.5 dB. Leaving out the fiber loss gives 6.7 dB; compare total loss with the budget, not one part of it.
8. Fiber transceivers rated 0 to 50 °C will go in an unheated pole-mounted box where winter nights reach -30 °F. What should the installer do?
Answer: Use units rated about -40 to +75 °C or a heated enclosure. -30 °F is about -34 °C, far below the 0 °C minimum, so the transmitter power and receiver sensitivity can drift out of specification or the units can fail. Choose industrial-temperature units (commonly -40 to +75 °C) or a heated, rated enclosure. Insulation alone does not keep an unpowered box warm.
9. A building has old Category 3 cable to each door. Can it carry 1000BASE-T to new IP access control readers?
Answer: No; Cat 3 is rated to 16 MHz and suits 10BASE-T. Category 3 is rated to 16 MHz and supports 10BASE-T; 1000BASE-T needs at least Category 5e (100 MHz) and uses all four pairs. Length within 100 m does not fix the bandwidth limit. Replace the runs with Cat 5e or better for gigabit devices.
10. UTP camera cables are being bundled in a ceiling space used for return air. The crew is using standard nylon cable ties. What does the NEC require?
Answer: Cable ties in plenums must be listed for low smoke and heat release. The NEC requires cable ties and similar accessories in spaces used for environmental air to be listed as having low smoke and heat release properties, the same idea as plenum cable. Plenum-rated cable doesn't excuse ordinary nylon ties. Tighten ties only snugly so the cable jacket isn't deformed.
11. To set up remote viewing, a technician needs the site's public IP address and the name of its ISP. What is the simplest way to find both?
Answer: Visit an IP lookup website from a computer on the site network. Devices on the LAN use private addresses such as 192.168.x.x, so ipconfig or the NVR show only the inside address. An IP lookup website sees the router's public address and reports it with the ISP's name. The public address may change unless the ISP provides a static IP.
12. A new camera cable passes a basic continuity tester, but the camera links only at 100 Mb/s and drops video at gigabit. What is the next step?
Answer: Test with a qualification tester for link quality at speed. A continuity tester proves only the wire map: each pin connected to the right pin. It can't show crosstalk, split pairs or poor terminations that stop a link reaching gigabit. A qualification tester checks whether the cable supports the target speed. T568A and T568B perform the same.
13. A PoE switch has a 370 W power budget and allocates power by class. Each 802.3at Class 4 camera is allocated 30 W. How many cameras can it power?
Answer: 12. 370 W / 30 W = 12.3, so 12 cameras fit; the 13th would exceed the budget even if the switch has more PoE ports. Some switches allocate by actual draw, which can allow more, but plan by class to be safe. Check both the per-port and total budget.
14. A PoE camera must be mounted 150 m of cable away from the nearest PoE switch. What is a standards-based solution?
Answer: Add a PoE extender part way, or run fiber to a media converter. Ethernet over twisted pair, including PoE, is limited to a 100 m channel whatever the cable category. A PoE extender placed within 100 m regenerates the signal and passes power on, or fiber with a powered media converter covers longer distances. More watts don't extend the data reach.
15. An old analog camera run of RG-59 is about 300 m long. The installer plans Ethernet-over-coax adapters that also send PoE. Why measure the cable's DC loop resistance first?
Answer: Its copper-clad steel center conductor may drop too much PoE voltage. PoE current flows through the center conductor and the shield, and many RG-59 cables use a copper-clad steel center conductor with high DC resistance. Over 300 m the voltage drop can leave the camera underpowered. Measure loop resistance and compare it with the adapter's limits. RG-59 is 75 ohm, not 50 ohm.

Get the full ETA TTT prep

Most popular · cancel anytime

Premium Monthly

$147/month
per exam
About $4.83 a day · a fraction of a retest fee, for the credential that gets you on the bid list
  • The RCDD exam: full prep for the v15 blueprint
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: numbers and formulas sheet, standards atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews monthly until you cancel. Cancel in two clicks from your account; you keep access until the end of the month you've paid for. No minimum term.

Best value · 3 months free

Premium Yearly

$1,323/year
per exam
Pay for 9 months, get 12. Save $441 against paying monthly.
  • The RCDD exam: full prep for the v15 blueprint
  • 3,000 practice questions + 6 full mock exams per exam
  • 800 flashcards + 60 key notes per exam, by topic, plus mind maps
  • Spaced repetition + mistakes bank
  • Readiness Score & detailed reports
  • Video lessons as they release
  • Content updates during your access
  • 5 bonuses: numbers and formulas sheet, standards atlas, study planner and more
  • Pass Guarantee: complete the prep, pass or 100% back

Renews once a year until you cancel. We email you before each renewal. Cancel any time from your account; you keep access until the end of the year you've paid for.

Pass Guarantee. Complete the full prep, sit your exam within 60 days, and if you don't pass we refund 100% of your subscription payments. See the requirements
Secure checkout by Stripe Card, Apple Pay, Google Pay Pass Guarantee

ETA TTT exam FAQ

How many questions are on the ETA TTT exam?

75 multiple-choice questions, with a time limit of 2 hours. Format: closed book; scratch paper and a non-programmable calculator are allowed. eta requires a hands-on training course from an eta-approved trainer or school, including building and testing a multimode fiber jumper and a cat 5e jumper that must pass ip video tests. this prep covers only the written knowledge exam.

What is the passing score for ETA TTT?

75%.

How much does the ETA TTT exam cost?

US$105 for the exam, with one free retake within one year of the first sitting; course fees are set by the school. Stand-alone certification, term 4 years, with maintenance required. BICSI fees can change without notice, so confirm on bicsi.org before you apply.

Which languages is the ETA TTT exam offered in?

English. ETA does not list other languages for TTT; confirm with ETA or your school.

Where do I take the ETA TTT exam?

ETA-approved schools and trainers, which run the required TTT course and hands-on exercises; the written exam is proctored by an ETA Certification Administrator online (Trapeza) or on paper.

Is this ETA TTT practice test free?

Yes. The 15-question practice test on this page is free, with an explanation for every answer and no signup. A free account also unlocks the complete study notes for the first topic. The full ETA TTT prep is Premium at $147 a month for this exam.

What's in the premium ETA TTT prep?

3,000 practice questions organized topic by topic (Network Cabling for Physical Security Systems: 375; Fiber Cabling, Distance and NEC Ratings: 375; Fiber Safety, Connectors and Mechanical Splices: 375; CCTV Fiber Transceivers and Optical Budgets: 375; UTP Cabling and Structured Cabling Layout: 375; UTP Connectors, Testers and Network Troubleshooting: 375; Power over Ethernet for Security Devices: 375; Coax for Ethernet and PoE: 375), 6 full-length timed mock exams of 75 questions, 800 flashcards and 60 comprehensive key notes split across all 8 topics, plus a mistakes bank and the Readiness Score.

Related practice tests

Exam details are summarized from the official candidate information available in October 2026. BICSI changes formats and fees, so confirm with ETA International (Electronics Technicians Association), accredited by ICAC under ISO/IEC 17024 before you book. RCDDQuizBank is not affiliated with BICSI or Pearson VUE.

Start the free test